96 *96mm Analog Panel Ammeter Squre Type 90 Degree With Red Line Alarm Output
1. Application:
- WD series meter are direct acting indicating analogue electrical measuring instruments. Measuring DC/AC current, voltage, frequency, power, power factor, phase sequence, synchroscope, position indication, network insulation moniroting, hours fun meter and other non-electric measurement;
- Mainly used in various AC/DC transmission and distribution system, power control panel and electric equipment for various industries such as marine,rail, aviation, chemical and explosive-proof,nuclear power, hig/mid voltage equipment, power generator set and control engineering. It is high end meter, and suitable for complicated environment to measure electric/non-electric energy;
- Also used on low voltage equipment, construction/mechanical equipment, various AC/DC power distribution system, electrical control panel and equipment. It is mid/low end meter, and suitable for universal environmental to measure electric/non-electrical energy.
2. Technical Parameters:
| Item |
Technical Data |
Standards |
| Technical Standard |
GB/T7676-1998 |
IEC60092-50 |
| Environmental Standard |
GB8355-1987 |
IEC92-504-74 |
| Safety Standard |
GB4793-20 |
IEC61010 |
| Working Temperature |
-40-65℃ |
|
| Temperature Infulence |
-13-33℃, 100% comply with accuracy class |
|
| Indicating Angle |
240°-270º (Synchroscope meter: 360º) |
|
| Color of Shell |
Black/white,board frame, terminal plate: black |
|
| Color of Dial Plate |
Black/white(other colors are available) |
|
| Mounting |
Vertical Installation |
|
| Dimension |
110*110mm, 80*80mm |
|
| 96*96mm, 72*72mm, 48*48mm |
|
| Overshoot |
Less than 20% when scale reaches to 2/3 |
|
| Insulation Withstand |
Circuit& shell: AC2600V/1 min(Water area) |
|
| Vibration Resistance |
24.5m/s2 |
|
| Impact Resistance |
147m/s2 |
|
| Material |
Shell/terminal board: ABS; Cover: Transparent Glass |
3. Ordering Instructions:

4. Standards:
- WD series analog meter are manufactured according to GB/T7676-1998 and IEC60051. And also meet the safety standard GB4793 and IEC61010;
- DIN43082 dimensions and penel cutouts conforme to GB/T1242 and IEC61554;
- Digital meters comply with the National Standard GB/T22264-2008;
5. Wiring Diagram

5. Certificates:
- WD series meters have passed ISO9001 and CE certificate; While marine type of meter meet to CCS certificate.
6. Case:
The external case of WD series analog panel meters consist of non-combustile ABS plastics whose Vicat temperature is 85℃, and it's foundation is manufactured with PPO plastic whose Vicat temperature is 130℃;
7. Ingress Protection Ratings:
WD series is regular IP40 and can be customized with IP52, IP54, IP56 and IP65.
Note: The ingress Protection ratings is not for the whole meter, only for the front parts of the meter includingthe frame, glass and seal plate.